FORCED AIR HEATERS
NOTE: All Heater Prices listed on this page include total price with Shipping!
Propane
Kerosene
The All-Pro PK1110 Forced Air Kerosene heater (110,000 BTU/HR) heats up to 2,550 sq. ft. 10.5hr run time on full 9 gallon tank. Quickly heats 50' X 51' X 8' area. Built in thermostat. Lighted power switch. Fuel gauge. HSI smart start technology. Tank size: 9 gallon. Shipping weight: 55lbs.
The All Pro PK165T Forced Air Kerosene heater (165,000 BTU/HR) heats up to 3,900 sq.ft. 11hour run time on full 13.5 gallon tank. Quickly heaters 50' X 78' X 8' area. Built in thermostat. Lighted power switch. Built in fuel gauge. 10" rugged pneumatic tires. HSI smart start technology. Tank size: 13.5 gallon. Shipping Weight: 70lbs |
How do I select the
correct size heater?
Use the chart below:
| Cubic feet of space to be heated** | Temperature Rise Required (Fahrenheit)* | BTU Capacity Required | ||||
| 20 degrees | 30 degrees | 40 degrees | 50 degrees | |||
| 5,000 | 14,000 | 20,000 | 27,000 | 34,000 | ||
| 7,000 | 19,000 | 28,000 | 38,000 | 47,000 | ||
| 10,000 | 27,000 | 40,000 | 54,000 | 67,000 | ||
| 15,000 | 40,000 | 60,000 | 80,000 | 100,000 | ||
| 20,000 | 54,000 | 80,000 | 107,000 | 133,000 | ||
| 30,000 | 80,000 | 120,000 | 160,000 | 200,000 | ||
| 50,000 | 133,000 | 200,000 | 266,000 | 333,000 | ||
* Temperature rise required is the difference
between actual temperature and desired temp.
** To determine cubic footage: Length x Width x Height of
structure.
Use this formula - Cubic Feet of Space x .133 x Heat Rise = BTU/HR
required.
Note: Use this size/selection chart as a guide only since
buildings vary according to type of construction, tightness and
insulation.
|